phone Icon 1-866-653-2278 contact us Icon Contact Us favourite Icon MyList Quick Order

ICR-225

ICR-225


The ICR-225 Thermally Improved Window Wall from Oldcastle BuildingEnvelopeĀ® offers two system depths for greater design flexibility.

  • • Thermaly improved with isolator clips between face and structural members
  • • Offers two system depths for greater design flexibility: 4-1/2" or 6"
  • • Infill: 1"
  • • 2-1/4" Sightline
  • • Inside glazed

The ICR-225 Thermally Improved Window Wall offers two system depths for greater design flexibility. The ICR-225 system is available in both 4-1/2? and 6? system depths with Type ā€œAā€ and Type ā€œBā€ installations for each depth. The Type ā€œAā€ system offers screw spline assembly with the verticals running through, while the Type ā€œBā€ system offers traditional design with continuous head and sill members. Incidental water control is available for Type ā€œBā€ systems when the alternate head detail is used. The ICR-225 Window Wall system offers a full line of accessories to accommodate various door framing and anchoring options.

  • • Overal system dimensions:
  • • 2-1/4" x 4-1/2"
  • • 2-1/4" x 6"
  • • Front set, inside-glazed configuration
  • • Two assembly options: featuring either continuous Verticals (Type ā€œAā€ System) or continuous Head and Sil members (Type ā€œBā€ System)
  • • Thermaly improved with isolator clips between face and structural members
  • • SSG glazing with zone bridges
  • • Door frame components 90° and 135° corners
  • • Optional incidental water management at continuous Head member (Type ā€œBā€ System)
  • • Two-color finishing capability
  • • Factory-painted Kynar 500Ā®/Hylar 5000Ā® finishes, meeting a l provisions of AAMA 2605
  • • Factory-anodized finishing
Show Less
Select File Type...
  • • Air Infiltration: <.06 CFM/SQFT (6.24 PSF) per ASTM E 283
  • • Static Water: 15 PSF per ASTM E 331
  • • Deflection Load: 35 PSF per ASTM E 330
  • • Structural Load: 52.5 PSFper ASTM E 330
  • • Thermal Performance per AAMA 1503
  • • NFRC Tested and Certified
  • •STC: As low as 35