phone Icon 1-866-653-2278 contact us Icon Contact Us favourite Icon MyList Quick Order

Reliance Cassette

Reliance Cassette


Reliance™ Cassette curtain wall is a 4-sided structurally glazed system allowing the installer to shop glaze the infill onto “cassette frames” using 3M™ VHB™ Structural Glazing Tape or structural silicone.

  • • 4-sided structurally glazed
  • • Shop glazed infill
  • • New or retrofit application onto existing curtain wall
  • • 2-1/2" Sightline
  • • 6-3/4" to 10-7/8" System depths
  • • Infill: 1"

Reliance™ Cassette Curtain Wall is a 4-sided structurally glazed system that allows the installer to shop glaze the infill onto “cassette frames” using 3M™ VHB™ structural Glazing Tape or Structural Silicone. These pre-glazed frames are then taken to the field and applied to a structural grid of standard Reliance™ or Reliance™-SS curtain wall framing, providing a 4-sided structurally glazed appearance with an overall system depth of 6-3/4", 8" or 10-7/8". This system can be used in either new construction or retrofit onto existing Reliance™ or Reliance™-SS installations. The system includes thermally improved door framing adaptors, which can accommodate the use of Oldcastle BuildingEnvelope® Thermal Entrances to complete a thermal elevation. Reliance™ Cassette can also accommodate exterior face caps to provide unique architectural framing features or transition to a standard Reliance™ or Reliance™-SS curtain wall installation.

  • • May be installed using Reliance shear block curtainwall or Reliance-SS screw spline curtain wall
  • • Captured perimeter or captured intermediate installation options
  • • Can transition from 4-sided silicone to standard Reliance or Reliance-SS with pre-engineered transition assemblies
  • • Accommodates ZS-30 projected and casement vents
  • • Accommodates low prole door frames for entrance doors
  • • Factory-painted Kynar 500®/Hylar 5000® finishes, meeting all provisions of AAMA 2605
  • • Factory-anodized finishing
Show Less
Select File Type...
  • • Air Infiltration: <0.06 @ 6.24 PSF per ASTM E283
  • • Static Water: 15 PSF per ASTM E331
  • • Dynamic Water: 15 PSF per AAMA 501
  • • Structural: 40 PSF (60 PSF overload) per ASTM E330
  • • Live Load: +/-1/4? per AAMA 501.7
  • • Seismic: Three Levels per AAMA 501.4
  • • Thermal Cycling: 180°F and 0°F for three (3) cycles per AAMA 501.5
  • • Sound: STC and OITC testing per ASTM E90
  • • Thermal: U-factor and CRF per AAMA 1503
  • • Thermal Simulations per AAMA 507
  • • NFRC Certified: U-factor, CR, SHGC and VT per NFRC 100,200 & 500